99无码不卡中文字幕在线视频_理论国产无码在线_久久综合国产乱子伦精免费_国产传媒日韩欧美成人动漫精品免费观看

產(chǎn)品中心

人IgG-Fc片段受體Ⅱ(FcgRII)酶聯(lián)免疫吸附檢測試劑盒
一鍵復(fù)制產(chǎn)品信息
ELK2071
規(guī)格: 價格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Human FcgRII(Receptor II For The Fc Region Of Immunoglobulin G) ELISA Kit
Reactivity: Human
Alternative Names: CD32; FCGR2A; FCG2; FCGR2A1; FCGR2; FCGR2B; FCGR2C; Fc Fragment Of IgG, Low Affinity IIa, Receptor; Low affinity immunoglobulin gamma Fc region receptor II-a
Assay Type: Sandwich
Sensitivity: 16.58 pg/mL
Standard: 3000 pg/mL
Detection Range: 46.88-3000 pg/mL
Sample type: serum, plasma and other biological fluids
Assay length: 3.5h
Research Area: CD & Adhesion molecule;Infection immunity;
Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human FcgRII. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human FcgRII. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human FcgRII, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human FcgRII in the samples is then determined by comparing the OD of the samples to the standard curve.

標準曲線

Concentration (pg/mL) OD Corrected OD
3000.00 2.201 2.108
1500.00 1.593 1.500
750.00 1.035 0.942
375.00 0.782 0.689
187.50 0.513 0.420
93.75 0.318 0.225
46.88 0.199 0.106
0.00 0.093 0.000

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant FcgRII and the recovery rates were calculated by comparing the measured value to the expected amount of FcgRII in samples.
Matrix Recovery range Average
serum(n=5) 88-103% 95%
EDTA plasma(n=5) 80-97% 88%
Heparin plasma(n=5) 92-106% 99%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of FcgRII and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 79-94% 87-96% 78-93% 82-90%
EDTA plasma(n=5) 95-102% 89-96% 87-98% 85-93%
Heparin plasma(n=5) 91-103% 86-92% 88-97% 89-97%