    Overview

    Product name: Human AGRN(Agrin) ELISA Kit
    Reactivity: Human
    Alternative Names: Agrin Proteoglycan
    Assay Type: Sandwich
    Sensitivity: 12.9 pg/mL
    Standard: 2000 pg/mL
    Detection Range: 31.25-2000 pg/mL
    Sample type: Serum, plasma, tissue homogenates and other biological fluids
    Assay length: 3.5h
    Research Area: Neuro science;Developmental science;Urology;
    Uniprot ID: O00468
    Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human AGRN. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human AGRN. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human AGRN, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human AGRN in the samples is then determined by comparing the OD of the samples to the standard curve.

    標(biāo)準(zhǔn)曲線

    Concentration (pg/mL) OD Corrected OD
    2000.00 2.135 2.031
    1000.00 1.625 1.521
    500.00 1.088 0.984
    250.00 0.876 0.772
    125.00 0.516 0.412
    62.50 0.345 0.241
    31.25 0.228 0.124
    0.00 0.104 0.000

    精密度

    Intra-assay Precision (Precision within an assay):CV%<8%

    Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

    Inter-assay Precision (Precision between assays):CV%<10%

    Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

    回收率

    Matrices listed below were spiked with certain level of recombinant AGRN and the recovery rates were calculated by comparing the measured value to the expected amount of AGRN in samples.
    Matrix Recovery range Average
    serum(n=5) 86-99% 92%
    EDTA plasma(n=5) 80-95% 87%
    Heparin plasma(n=5) 90-105% 97%

    線性

    The linearity of the kit was assayed by testing samples spiked with appropriate concentration of AGRN and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
    Matrix 1:2 1:4 1:8 1:16
    serum(n=5) 93-105% 79-86% 87-103% 85-97%
    EDTA plasma(n=5) 87-90% 87-98% 85-96% 85-95%
    Heparin plasma(n=5) 87-98% 85-96% 92-102% 81-93%