    產(chǎn)品中心

    人血管內(nèi)皮生長因子A(VEGFA)酶聯(lián)免疫吸附檢測試劑盒
    一鍵復(fù)制產(chǎn)品信息
    ELK1129
    規(guī)格: 價(jià)格:
    48T ¥1680.00
    96T ¥2400.00

    Overview 文獻(xiàn)(8)

    Product name: Human VEGFA(Vascular Endothelial Growth Factor A) ELISA Kit
    Reactivity: Human
    Alternative Names: VEGF; VEGF-A; VPF; Vascular Endothelial Cell Growth Factor A; Vascular Permeability Factor
    Assay Type: Sandwich
    Sensitivity: 6.4 pg/mL
    Standard: 1000 pg/mL
    Detection Range: 15.63-1000 pg/mL
    Sample type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
    Assay length: 3.5h
    Research Area: Cytokine;Apoptosis;Tumor immunity;
    Uniprot ID: P15692
    Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human VEGFA. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human VEGFA. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human VEGFA, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human VEGFA in the samples is then determined by comparing the OD of the samples to the standard curve.

    標(biāo)準(zhǔn)曲線

    Concentration (pg/mL) OD Corrected OD
    1000.00 2.135 2.063
    500.00 1.562 1.490
    250.00 0.997 0.925
    125.00 0.682 0.610
    62.50 0.395 0.323
    31.25 0.273 0.201
    15.63 0.135 0.063
    0.00 0.072 0.000

    精密度

    Intra-assay Precision (Precision within an assay):CV%<8%

    Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

    Inter-assay Precision (Precision between assays):CV%<10%

    Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

    回收率

    Matrices listed below were spiked with certain level of recombinant VEGFA and the recovery rates were calculated by comparing the measured value to the expected amount of VEGFA in samples.
    Matrix Recovery range Average
    serum(n=5) 78-96% 87%
    EDTA plasma(n=5) 78-92% 85%
    Heparin plasma(n=5) 80-95% 87%

    線性

    The linearity of the kit was assayed by testing samples spiked with appropriate concentration of VEGFA and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
    Matrix 1:2 1:4 1:8 1:16
    serum(n=5) 86-94% 85-95% 89-99% 85-95%
    EDTA plasma(n=5) 89-97% 85-94% 79-96% 85-99%
    Heparin plasma(n=5) 79-93% 89-97% 85-94% 87-101%